Finden Sie schnell test tester für Ihr Unternehmen: 363 Ergebnisse

30kV 10mA DC Tester PT30-10 MK3

30kV 10mA DC Tester PT30-10 MK3

±30kVdc output voltage. 10mA output capability. Both voltage and current metered on HV outputs. Automatic earth system for dumping capacitive loads. HV output plug & socket system. Key operated supply switch to prevent unauthorised operation. Zero-volt interlock. Visual indication of test piece failure. Automatic mains voltage selection. The PT30-10 Mk3 high voltage dc test set is designed to perform tests on installed cable and jointing systems. The 30kV 10mA DC tester has a variable output voltage with a maximum of ±30kVdc, with a maximum charging capability of 10mA. A zero-volt interlock is fitted that prevents the output being switched on unless the output control is at zero. The units include an automatic load discharge system that discharges the cable under test when the output is switched off or a breakdown occurs. The internal dumping system can discharge a maximum of 2.5kJ on each output, corresponding to 4µF at 30kV. In the event of a test object failure, the overload circuit will automatically switch off the output voltage and earth the output via the internal discharge circuit. A manual DP40 discharge probe is also supplied as standard with the PT30-10 MK3, 30kV 10mA DC Tester, allowing higher load capacitances to be safely discharged. The mk2 units introduce automatic 115/230V mains voltage selection, allowing easy transition between site voltages. The output voltage is metered by two large, linear, analogue instruments marked 0-30kV. Test object current is metered by two further analogue instruments with 0-10 scale marking. The meters read 0-10mA directly, or 0-1mA when the ÷10 push button is operated. The HV output from the unit uses a high quality plug and socket system, allowing for easy cable replacement.
18kV 10mA DC Tester PT18-10 MK2

18kV 10mA DC Tester PT18-10 MK2

Ultra lightweight (6.9kg) 1-200Adc test current with <2.5% ripple Supplied with standard 3m output lead set 0.1μΩ resolution mV, A, and m/μΩ displayed simultaneously USB memory key for data storage USB keyboard for comment entry Pre-settable test current with three buttons to store user test currents Large back-lit liquid crystal display Universal supply voltage 90-264V Optional current clamp to allows testing of objects with both sides earthed The PT18-10 mk2 high voltage dc test set is designed to perform tests on installed cable and jointing systems. The 18kV 10mA DC Tester has a variable output voltage with a maximum of ±18kVdc with a maximum charging capability of 10mA. A zero-volt interlock is fitted that prevents the output being switched on unless the output control is at zero. Units include an automatic load discharge system that discharges the cable under test when the output is switched off or a breakdown occurs. Internal dumping system can discharge a maximum of 2.5kJ on each output, corresponding to 10µF at 18kV. In the event of a test object failure, the overload circuit will automatically switch off the output voltage and earth the output via the internal discharge circuit. A DP20 discharge probe is supplied as standard with the PT18-10 mk2, 18kV 10mA DC Tester, allowing higher load capacitances to be safely discharged. The 18kV 10mA DC Tester has an internal fail-safe automatic discharge system with the following ratings: Max. discharge voltage (kVdc) 20kVdc Highest discharge energy 2.5kJ Highest discharge capacitance 10μF Max. discharges per hour 4 The automatic discharge switch is controlled by a solenoid. It may produce a noticeable hum when the HT output is energised. Output voltage is metered by two large, linear, analogue instruments marked 0-20kV. Meanwhile, current is metered by two further analogue instruments with 0-10 scale marking. The meters read 0-10mA directly, or 0-1mA when the ÷10 push button is operated. The HV output from the unit uses a high quality plug and socket system, allowing for easy cable replacement. High voltage plugs are protected in transit by plastic covers and are fully de-mountable. Screened 5 metre long high voltage output cables are provided with the equipment terminated with large clips. The mk2 units introduce automatic 115/230V mains voltage selection. That along the padded bag ensure maximum protection during transit.
TD 5000 Tan delta test set

TD 5000 Tan delta test set

The high-voltage generator TD 5000 is a complementary module of STS serie. TD 5000 designed to perform Tan Delta measurements, dissipation factor and capacitance of transformer and bushing at the frequency of the mains or in a wide frequency range. Main features Optional module for STS 5000 and STS 4000 test set, standard module for STS 3000 light Tan Delta, capacitance, dissipation factor measurements and for exciting current test Output voltage from 12 V up to 12 kV Variable output frequency: 1 – 500 Hz PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report Compact and lightweight Patented technology Tests performed Tangent Delta Capacitance Dissipation factor
200ADM-P Secondary Current Injection Test Set

200ADM-P Secondary Current Injection Test Set

The 200ADM-P is a current injection system with a wide range of advanced features including phase shift, data storage and harmonic analysis. 0-200A output current True RMS metering with 1 cycle capture Variable auxiliary ac voltage/ current output with phase shift Auxiliary metering input V, f, Φ, Z, P, S, PF, CT ratio, harmonics & more Variable auxiliary output 12-220Vdc Multi-function auto-ranging timing system Current limit mode for fine control Data storage to USB memory key including waveform & harmonics USB keyboard/printer interface Automatic mains voltage selection The 200ADM-P Secondary Current Injection Test Set has a range of outputs allowing injection of currents between 1mA and 200A. Voltages up to 240V are available on the main outputs allowing high impedance current relays to be tested. True RMS metering with single cycle capture is provided. 4 current ranges allow the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used throughout for safe, reliable convenience. The 200ADM-P Secondary Current Injection Test Set has a flexible auxiliary ac output that can be used at up to 260V for voltage relays or up to 10A for current relays. The phase and frequency of this output are fully adjustable. This combination of voltage and current allows testing of relays that require two voltages, one voltage and one current or two currents. An auxiliary metering module is provided that meters ac and dc voltage, current and frequency from the auxiliary outputs or external signals. The module can also take measurements in conjunction with the main current output to meter phase angle, power, impedance, CT ratio and harmonics. A variable stabilised DC supply with current limit is provided to power the relay under test. WEIGHT 22.6 kg DIMENSIONS 500 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Output lead set Mains lead Sparefuses USB keyboard USB memory key Shoulder strap (except Pelicase unit) OPTIONAL ACCESSORIES 100ADM-F, Part no. 006 100AL Mk2 / Mk3, Part no. A199-0003
100ADM MK5 Secondary Current Injection Test Set

100ADM MK5 Secondary Current Injection Test Set

0-100A output current True RMS metering with single cycle capture Auxiliary DC and AC output Multi-function auto-ranging timing system Current limit mode for fine control Automatic mains voltage selection Thermal and over-current protection The 100ADM mk5 Secondary Current Injection Test Set provides commissioning and maintenance engineers with a flexible system for testing protective systems. It has an easy to understand panel layout and a simple user interface. The status of every function can be seen at a glance, and there are no complex menus to navigate. The 100ADM mk5 keeps the familiar user interface of previous models but adds a new metering system that accurately measures the RMS of a single cycle. It also features a new current limit mode to provide very fine control of very low currents, even into low impedance loads. Current limit mode also assists in testing self-powered overcurrent protection as fitted to many 11kV ring main units. The unit has a range of outputs allowing injection of currents as low as a few mA and as high as 100A. Voltages up to 240V are available on the main outputs, allowing high impedance current relays and voltage relays to be tested. Four true RMS metering ranges are provided, allowing the full scale of the meter and trip level to be set independently of the selected output. Industry standard safety connectors are used on all inputs and outputs for convenience, reliability and safety. The 100ADM Mk5 Secondary Current Injection Test Set is comprehensively protected by overcurrent, duty cycle and thermal trips, and keeps the user fully informed of any trip condition. A stabilised DC supply is provided to power the relay under test, along with an independently switched and isolated 110V AC output. The back-lit display on the 100ADM mk5 is bright and clear with a wide viewing angle. The results of a test can be seen here as they appear on the display A very flexible two channel timing system is provided, allowing trip times, reset times and re-close times to be quickly measured to a high degree of accuracy. The timer auto-ranges to measure from 1ms to 99999.9s. The 100ADM can be used to test many types of single phase secondary protection including: 27/59 Over and under voltage relays 37 Under current 51 IDMT relays 50/76 Instantaneous overcurrent 59G Neutral voltage displacement 79 Auto-reclosers 2 Time delay relays 51G/50G Earth fault relays 67 Directional overcurrent (basic tests) 52 Miniature circuit breakers Tripping relays Thermal relays 90V Voltage regulating relays WEIGHT 23.9 kg DIMENSIONS 560 × 456 × 265 mm SUPPLIED ACCESSORIES Operating manual Mains lead Output lead set Spare fuses Carry strap OPTIONAL ACCESSORIES 100ADM-F, Part no. 006
TDX 5000 Tan Delta and capacitance test set

TDX 5000 Tan Delta and capacitance test set

TDX 5000 is developed as a compact solution for high voltage Capacitance and Tan Delta (Dissipation Factor) measurements. Using the reactor option, TDX 5000 can also perform tests on rotating machines. Main features Fully automatic Variable output frequency: 1 – 500 Hz Output voltage up to 12 kV Tan Delta, capacitance, dissipation factor measurements and exciting current test RCTD – compensating reactor module allows increasing the test current and getting the maximum test voltage with high capacitive burdens PADS – Power Apparatus Diagnostic Software for automatic testing, assessment and report USB interface and Ethernet interface for PC connection Patented technology for capacitance and Tan Delta measurement Light and compact Tests performed Tangent Delta Capacitance
T 1000 PLUS Secondary injection relay test set

T 1000 PLUS Secondary injection relay test set

Multi-tasking test set designed for testing relays and transducers Max current output: 250 A Max AC voltage output: 250 V Max DC voltage output: 300 V Frequency generator: 15 ÷ 550 Hz Phase angle shifter Battery simulator 20 ÷ 260 V DC Oscilloscope function for current and voltage USB port – Microprocessor controller Test results and settings saved into local memory TD 1000 Plus model with two current outputs and high power at 15 Hz. T1000 PLUS is a protective relay test set especially designed to give the commissioning engineers a multitasking and highly reliable testing equipment. Tests performed Distribution relays Smart grid relays Single phase relays High burden relays
Bump Tester und Gas Kalibrator

Bump Tester und Gas Kalibrator

Gesetzliche Vorschriften und die Notwendigkeit des täglichen Stoßprüfens erzeugen ein starkes Bedürfnis von Gastests. Gasdetektoren spielen eine wichtige Rolle für die Sicherheit von Menschen und Anlagen. Calibration Gas Description Ni-Br regulator Stainless steel regulator Non-reactive gases Suitable Suitable H2S Suitable Suitable SO2 Suitable Suitable NO Not recommended Suitable NO2 Not recommended Suitable Cl2 Not suitable Suitable NH3 Not suitable Suitable HCL Not suitable Suitable PH3 Not suitable Suitable SiH4 Not suitable Suitable HCN Not suitable Suitable
Stoil Cell For dielectric oil test

Stoil Cell For dielectric oil test

Oil cell for the HV test of dielectric oil The option allows the testing of the insulation characteristics of the oil by checking if there is no contamination. Main features Maximum test voltage: 12 kV Cell volume: about 1l Capacitance of the empty cell: 60 pF. Tests performed Tangent Delta
DRTS 66 – Automatic relay test set

DRTS 66 – Automatic relay test set

DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available. Main features Manual control of the display 6 Current and 6 Voltage generetors plus 1 battery simulator outputs Current outputs : 6 x 32 A, 3 x 64 A, 1 x 128 A Power outputs: 6 x 430 VA, 3 x 860 VA, 1 x 1000 VA Voltage outputs: 6 x 300 V at 100 VA High accuracy outputs: better than 0.05% IEC 61850 protocol interface USB and ethernet interface Advanced testing and data management software TDMS Complete library of relays from the major manufacturers Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays High burden relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 66 – Automatic relay test set

DRTS 66 – Automatic relay test set

DRTS 66 is the most powerful diagnostic test set designed to perform accurate tests on protection relays, transducers, energy and power quality meters. This advanced test equipment is also thought to satisfy all the needs related to commissioning and substation maintenance. 6 Current and 6 Voltage generators simultaneously available. Main features Manual control of the display 6 Current and 6 Voltage generetors plus 1 battery simulator outputs Current outputs : 6 x 32 A, 3 x 64 A, 1 x 128 A Power outputs: 6 x 430 VA, 3 x 860 VA, 1 x 1000 VA Voltage outputs: 6 x 300 V at 100 VA High accuracy outputs: better than 0.05% IEC 61850 protocol interface USB and ethernet interface Advanced testing and data management software TDMS Complete library of relays from the major manufacturers Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays High burden relays Low power relays DC relays Energy meters Transducers Power quality meters
DRTS 6 Automatic relay test set

DRTS 6 Automatic relay test set

Main features Multi-tasking relay test equipment designed for testing protection relays, energy meters, transducers Output: 6×15 A (80 VA); 4×300 V (85 VA); 1×260 V DC High accuracy outputs: 0.1 %; 0.05% (HP) Analog measurement inputs IEC 61850 protocol interface USB and RS232 port Controlled by PC laptop or local control by PDA Tests performed Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays Low power relays DC relays Energy meters Transducers Power quality meters
T 3000 Primary current injection test set

T 3000 Primary current injection test set

T 3000 is a primary current injection testing system designed to perform primary tests requested in substations commissioning. It allows to perform different tests and measurements on current transformers, voltage transformers, power transformers, protection relays, energy meters and transducers Main features Multi function primary test system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities 3000 V AC high-pot test Generates up to 800 A (option up to 4000A with high current booster) Microhmmeter function (option): up to 400A DC RS232 interface for pc connection Possibility to store test results in T 3000 local memory (up to 500 results) Compact and lightweight. Tests performed CT ratio CT ratio voltage mode CT polarity CT burden secondary side CT excitation curve CT knee voltage CT winding resistance Burden resistance VT ratio VT polarity VT burden secondary side PT ratio PT winding resistance Distribution relays Smart grid relays Single phase relays High burden relays CB operation time
DRTS 3 PLUS Automatic relay test set

DRTS 3 PLUS Automatic relay test set

DRTS 3 PLUS power system simulator is designed to give the highest accuracy when testing and calibrating protective relays, energy meter, transducer and power quality devices. This diagnostic and calibration equipment is the perfect solution to perform automatic testing on protection devices. Main features Multi-tasking relay test equipment designed for testing protection relays, energy meters, transducers Output: 3×15 A (100 VA); 4×300 V (85 VA); 1×260 V DC High accuracy: better than 0,05% Analog measurement inputs IEC 61850 communication Protocol interface USB and RS232 port Controlled by PC laptop or local control by PDA Lightweight Applications Transmission relays Distribution relays Smart grid relays Single phase relays Three phase relays Multi phase relays Low power relays DC relays Energy meters Transducers Power quality meters
eKAM Electronic primary injection test set

eKAM Electronic primary injection test set

eKAM is the new fully automatic electronic primary injection test equipment. e KAM test system includes two portable units: one control unit with a large graphical display, that adjusts the output, and one current unit (up to 2000, 3000, 5000A). It can also perform Step and Touch tests and ground resistance tests. Main features Fully automatic Two portable units: control and current units High current output: up to 2000 A, 3000 A and 5000 A Variable output frequency: 15 – 500 Hz CT ratio, burden and polarity test Large graphic display Advanced Test & Data Management Software for test set control, results storage and analysis Step & touch plus ground resistance tests with STLG option Reduced timing test USB interface and Ethernet interface for PC connection IEC 61850-9-2 sample values protocol interface Compact and lightweight Tests performed High current 2000, 3000, 5000, 7000 A CT ratio; CT polarity CT burden secondary side CT IEC 61850-9 CB operation time Earth impedance Line impedance Step & touch voltage
PT18-10 MK2 Test Set

PT18-10 MK2 Test Set

PT18-10 Mk2 wurde für die sichere Prüfung von Kabel- und Verbindungssystemen entwickelt, mit variabler Ausgangsspannung und automatischem Lastentladesystem. ±18kV Gleichspannungsausgang 10mA Ausgangskapazität Sowohl Spannung als auch Strom werden an den Hochspannungsausgängen gemessen Automatisches Erdungssystem zum Entladen kapazitiver Lasten Hochspannungsausgang mit Stecker- und Buchsensystem Schlüsselschalter zur Verhinderung unbefugter Bedienung Null-Volt-Verriegelung Visuelle Anzeige bei Versagen des Prüflings Automatische Netzspannungsauswahl Datenblatt Bedienungsanleitung
PT15-10S Mk2 Test Set

PT15-10S Mk2 Test Set

Hochleistungs-PT15-10S Mk2 Gleichstrom-Testgerät: variable Ausgangsspannung bis zu 15 kV DC, automatische Lastentladung und zuverlässige Messungen für genaue Tests 0 bis 15 kVdc Ausgangsspannung 10 mA Ausgangskapazität Sowohl Spannung als auch Strom werden am Hochspannungsausgang gemessen Automatisches Erdungssystem zur Entladung kapazitiver Lasten Hochspannungsausgang Stecker &amp; Buchse Mit Schlüssel betätigter Versorgungsschalter zur Verhinderung unbefugter Bedienung Null-Volt-Verriegelung Visuelle Anzeige bei Versagen des Prüfstücks Kompaktes Gerät mit leichtem, isoliertem Gehäuse Datenblatt Bedienungsanleitung
PCU1-SP MK2 Primary Current Injection Test Set

PCU1-SP MK2 Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The PCU1-SP mk2 is a medium powered primary current injection set offering output currents up to 5000A (11.5kVA for 40seconds). The system consists of a separate control unit containing all metering and control functions and a loading unit, such as the NLU200, NLU2000 or the NLU5000, that provides the high current output. The PCU1-SP mk2 are ideally suited to primary current injection, stability testing and circuit breaker testing. In addition, the SP version offers direct-reading CT ratio and polarity tests and a 100A secondary injection output. Two loading units are available, delivering a maximum output current of 2000A or 5000A. Each loading unit has three output taps to allow for a wide range of load impedances. For example, the NLU5000 may be configured to either give a maximum current of 5000A on the 2.3V range, 2500A on the 4.6V range or 1250A on the 9.2V range. *The above is an image of the PCU1-SP and Loading Unit The control unit is rated at 11.5kVA with a 2 second overload capability of 23kVA using pulse mode. All metering is digital and a memory facility is provided to hold the current reading when the output trips or is switched off. The current is switched by a solid state device and is automatically switched off when the device under test trips. The PCU1-SP systems have a high accuracy timing system, allowing timing tests to be carried out to a resolution of 1ms. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available to test under and over current devices, re-closers, under and over voltage devices, current trips and circuit breakers. A full range of high current output leads are available to complement the system in a range of lengths. WEIGHT 26 kg DIMENSIONS 450 × 275 × 305 mm SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set OPTIONAL ACCESSORIES Trolley mounting system, Part no A204-0005 100ADM-F, Part no. 006 100AL MK2 / MK3 Lead Set, Part no. A199-0003
HV TROLLEY2 High Voltage AC Test System

HV TROLLEY2 High Voltage AC Test System

20kVA output capability 0-3kV to 0-15kV options available Accurate digital metering Key operated supply switch Dual overload protection Variable electronic trip 10-110% of rated output Voltage and current metering Optional 5s – 5min test timer External 24V interlock and zero-volt interlock Emergency stop switch The HV trolley2 series of units are high power AC flash test sets with a 20kVA output capability. Single Trolley Version The maximum output voltage can be customised to be any voltage up to 15kV. The unit is housed in a rugged aluminium enclosure with a cover to protect the control panel. It is mounted on wheels to allow easy movement within a production environment. The HV trolley2 is provided with accurate digital voltage and current metering and a variable electronic trip. An external interlock input is also fitted to the unit. Outputs are provided to drive 24V warning beacons. The HV output is connected to the test object by a high voltage cable 5m long.
CU-Ps Primary Current Injection Test Set

CU-Ps Primary Current Injection Test Set

5kA maximum output current (higher overload currents for 2s) Multi-function digital timing system Digital true RMS memory ammeter Solid state switching 200A, 2000A and 5000A loading units Three range outputs on loading units Rugged, compact design Optional trolley mounting of system Secondary injection up to 100A Auxiliary metering input Direct reading CT ratio and polarity The CU-Ps primary current injection test set is ideally suited to commissioning and maintenance testing where very high currents are required. The system consists of separate control and loading units for maximum flexibility. The control unit contains all control and metering circuitry, and is linked to the loading unit by control and metering cables. The control unit may be used with one of two loading units providing between 5000A or 6000A for 5 minutes or up to 10 or 12kA for short periods. Each loading unit has two outputs which may be connected in series or parallel for maximum flexibility. For example, the PLU-6k may be configured to either give a maximum current of 3000A at 6.6V or 6000A at 3.3V. The control and loading units are each housed in tough steel cases fitted with castors and protective lifting handles. The loading units have a small plan area to allow them to be positioned as close as possible to the test object, minimising power requirements and maximising the available current. The CU-Ps control unit is shown here with a PLU-6k loading unit. This combination may be used to inject currents of up to 6000A for 5 minutes or 12000A for 1 second. The CU-Ps primary current injection test set is ideally suited to all primary current injection tasks, including testing under and over current relays, circuit breakers and CT ratio testing. The control unit is rated at 20kVA and has digital metering. A memory facility is provided on the metering to hold the current reading when the output trips or is switched off. The current is automatically switched off when the device under test trips. The CU-Ps systems have a high accuracy timing system with 1ms resolution. Selection for normally open or normally closed contacts is automatic, and the status of the contacts is shown on the front panel. Timing modes are available for under and over current devices, reclosers, under and over voltage devices, current trips and circuit breakers. The AC output current is metered by a true RMS memory ammeter (acquisition time 20ms) with a liquid crystal display. The current metering has 3 ranges corresponding to 10%, 50% and 100% of the maximum rating of the loading unit. In addition, a 200% metering range is enabled in pulse mode for the 0.2s, 0.5s and 1s settings only. The CU-Ps systems have a flexible timing system with two contact inputs and 5 operating modes. Each contact circuit automatically selects for N/O or N/C contacts, and the status of each contact input is shown by an LED. The timing channels may also be triggered by a dc voltage between 24 and 240V. *Pulse mode applies current to the load for a maximum of the specified time. If contact set 1 changes state or the current drops below 20% of the metering range during the pulse time, the timer is stopped. The maximum output current is increased in pulse mode. The maximum obtainable current is set by the impedance of the test object and output leads. **Current operated mode is used to time circuit breakers with no auxiliary contacts. The timer is started when the current exceeds 20% of the selected metering range (e.g. 1000A on the PLU-5k 5000A range). The timer stops when the current falls. All test results from the CU-Ps can be stored in a USB memory key. The unit has a real-time clock to time and date-stamp all results. To log the results, first enter a comment for your results using the optional keyboard, and then select AUTO STORE. Whenever the timer stops, the time, current and all other parameters are added to a spreadsheet file on the USB key. You can then view the current set of results on the display or take the USB key out and open the file on your PC. All results are stored in a folder on the USB key named with the test date in a file named with the time. The CU-Ps primary current injection test sets and loading units are CE marked and are designed to meet the requirements of BS EN61010. The system is protected by electronic trips on the outputs, circuit breaker and fuse on the mains input, and a circuit breaker on the control unit output. The unit also has a duty cycle trip on the loading unit output and thermal protection. WEIGHT 115 kg DIMENSIONS 660 × 400 × 740 mm OPTIONAL ACCESSORIES A range of output lead sets are available to complement the CU-Ps system with current ratings between 3000A and 6000A. The leads are double insulated and have good flexibility. SUPPLIED ACCESSORIES Operating manual Mains lead Spare fuse set
Cirris 4200 Kabeltester

Cirris 4200 Kabeltester

Der Kabeltester Cirris 4200 kombiniert die leistungsstarke Cirris OS-Software mit dem intuitiven Cirris-Adaptersystem zu einem leistungsfähigen Tester Produktmerkmale Qualität ohne überteuert zu sein : Erschwinglich für kleine Geschäfte und skalierbar für größere Betriebe. Alle wesentlichen Tests : Test auf Unterbrechungen, Kurzschlüsse, Fehlverdrahtungen und intermittierende Fehler. Testen Sie auch Komponenten wie Widerstände, Dioden und Kondensatoren. Sicherheit: Stellen Sie sicher, dass Testprogramme und Systemeinstellungen zwischen Einrichtungen und Bedienern gleich sind, indem Sie ausgewählte Testerfunktionen sperren, um System- und Testprogrammänderungen zu verhindern. Schnelles Testen : Innovative Technologie und effiziente Algorithmen reduzieren den Zeitaufwand für das Testen. Kompakt : Klein, leicht und in sich geschlossen für eine einfache Bewegung in der Produktionshalle. Erweiterbar für große Baugruppen : Erweiterungsboxen schaffen bis zu 1024 Testpunkte (128 Punkte pro Box). Leicht zu erlernen: Keine fortgeschrittenen Fähigkeiten oder Schulungen erforderlich, um mit dem Testen zu beginnen. Integriertes Networking : Teilen Sie Testprogramme und Drucker einfach mit mehreren Geräten. Anpassung von Testprogrammen : Passen Sie Etiketten, Berichte, digitale IO usw. in einzelnen Testprogrammen oder global an. Mehrere Sprachoptionen : Vermeiden Sie Fehler, die durch Sprachbarrieren verursacht werden. Schneller Testaufbau: Das Cirris-Adaptersystem bietet kostengünstige, austauschbare Vorrichtungen. Übergang von 1100 : Verwenden Sie bereits im 1100R+ eingerichtete Testprogramme und Berichte auf dem 4200. Langlebig : Testen Sie Tausende von Kabeln ohne Angst vor Geräteausfällen. Optionale PC-Steuerung : Verbinden Sie sich mit einem PC und erweitern Sie die Möglichkeiten mit der Cirris Easy-Wire™-Software. Vollfarb-Touchscreen : Zeigen Sie Anweisungen und Testergebnisse auf dem 7-Zoll-Display an.
DUTEST® – Benning Durchgangs- und Leitungsprüfer

DUTEST® – Benning Durchgangs- und Leitungsprüfer

Zuverlässige Ermittlung von Falschverdrahtungen, Kontaktierungsfehler und Kabelunterbrechungen Schnelles Auffinden von defekten Sicherungen, Leuchtmitteln, Leitungen und Kurzschlüssen Beschreibung DUTEST® Durchgangs- und Leitungsprüfer Zuverlässige Ermittlung von Falschverdrahtungen, Kontaktierungsfehler und Kabelunterbrechungen Schnelles Auffinden von defekten Sicherungen, Leuchtmitteln, Leitungen und Kurzschlüssen Anzeige von hochohmigen (0 – 90 kΩ) und niederohmigen (0 – 900 Ω) Widerständen Akustische Anzeige über lautstarken Prüfsummer Optische Anzeige über kontrastreiche Leuchtdioden Leuchtstarke Taschenlampenfunktion Fremdspannungsgeschützt bis 400 V Anzeige: LED Durchgangs- prüfung: Summer + LED 900 Ω/90 kΩ Taschenlampenfunktion: Ja/Glühbirne Schutzart: IP 30 Art-Nr.: 050155
HTM - Hydrantentester

HTM - Hydrantentester

inkl. Standfüße, Batterie, Handbuch, Kalibrierzertifikat Nennweiten DN80 und DN100 • Durchflussmessbereich: 100-1500 l/min. bzw. 200 – 2500 l/min • Druck-Messbereich: 0-16 bar (0-10 bar; 0-6 bar) Anzeige am Manometer oder Datenlogger • Alu-Tragegriffe und Standfüsse mit Gummipuffer • Einlauf / Auslauf Beruhigungsstrecken 500 mm lang inkl. Standfüsse für einfachen Auf-/Abbau des Hydrantentesters • Digitalanzeige vor Ort für Durchfluss in l/min; bar; m³/h; m³ • Batteriebetrieb • Integrierter Datenlogger mit Impulsausgang bzw. 4-20 mA Ausgang für ext. Aufzeichnungsgerät / Datenlogger • Manometer; Digitalmanometer oder Drucksensoren mit 4-20 mA für ext. Aufzeichnungsgerät / Datenlogger
PRÜFBALL SPB ANALOG – Robuster analoger Spannungsprüfer mit Gummigehäuse

PRÜFBALL SPB ANALOG – Robuster analoger Spannungsprüfer mit Gummigehäuse

Sein einzigartiges Gehäuse aus Gummi kapselt das Messwerk ballartig ein und schützt optimal gegen harte Stöße, Wasser, Staub und elektrischen Schlag. Das macht den Spannungsprüfer unverwüstlich, sicher und langlebig. Der Prüfball SPB ist ein gummigekapselter Spannungsprüfer für den sicheren Einsatz in der Energieversorgung – genau, robust und wartungsfrei. Spannungsprüfer: präzise Anzeige der Spannung 20 – 500 V AC/DC / 50 V – 1000 V AC/DC extrem Spannungsfest – CAT IV 1000 V – VDE zertifiziert eindeutige LED-Anzeige für gefährliche Spannung Lastzuschaltung für Störspannungen und RCD-Auslösung vollständige Spannungsanzeige ohne Batterie – wartungsfrei präzises, störsicheres Drehspul-Messwerk mit direkter Anzeige Durchgangsprüfer: schneller Durchgangstest Phasen- und Drehfeldrichtungsprüfer: Phasenprüfer mit roter LED Anzeige Drehfeldprüfer mit LED Anzeige rechts / links Controller-überwachte Prüfung mit Fehlererkennung zur Vermeidung von Falschaussagen Phasen- und Drehfeldrichtungsprüfer können mit Handschuhen genutzt werden weitere Funktionen: Sicherheitsgehäuse aus Vollgummi extrem stoßfest Prüfelektroden mit Gewinde zum Aufschrauben von Zubehör leichte Bedienung Isolierungsfehler Erkennung durch zweifarbige Leitungsisolierung extrem stabiles Gehäuse, auch bei Kälte IP 65 – wasserdicht
MultiTest HT700 – ARC DGUV Vorschrift 3 Tester mit Touchscreen

MultiTest HT700 – ARC DGUV Vorschrift 3 Tester mit Touchscreen

DGUV V3 Gerätetester zur Prüfung elektrischer Betriebsmittel inkl Schweißgeräte Prüfung im Rahmen der DGUV V3, BetrSichV gemäß: • DIN VDE 0701-02:2008 (EN 62638) Prüfung elektrischer Geräte/Arbeitsmittel • DIN VDE 0751-1:2015 (EN 62353): Prüfung medizinisch elektrischer Geräte, wie Pflegebetten etc. • DIN VDE 0544-4 (EN 60974-4): Prüfung elektrischer Schweißgeräte Leistungsmerkmale: • Prüfung von mobilen Personenschutzschaltern PRCD (2-/3-polig) Typ S, S+, K • Prüfung von Fehlerstromschutzeinrichtungen RCD Typ AC, A, F, B, B+ • Schnittstellen: WLAN, RJ45 (LAN), USB, SD-Kartenslot und Bluetooth® • Standard, erweiterte und kundenspezifische Sichtprüfungen • Prüfung von Lichtbogenschweißeinrichtungen • Gerätetester kann in IT-Netzen betrieben werden • Datenbankverwaltung von Kunden & Betriebsmitteln mit ID-Nr. • Erstellung und Zuweisung individueller Prüfabläufe und -intervalle • Automatischer und manueller Prüfablauf einstellbar • Geringe Betriebskosten, kostenfreie Updates über WLAN, LAN, USB • Touch-Screen für Gesten, Softkey-Tastatur (QWERTZ), grafische Bedienfelder, „On-/Off-Slider“ zum Aktivieren/Deaktivieren von Funktionen • Unbegrenzte Datenspeicherung über SD-Karte • Messergebnis mit eindeutiger GUT / SCHLECHT Anzeige • Komplett – ein Gerätetester für alle VDE Geräteprüfungen
20A DC booster Winding resistance test

20A DC booster Winding resistance test

Maximum output current: 20 A DC Maximum power on output sockets: 400 W Current output switch: controlled by STCS Current output amplitude: controlled by STS 5000 or STS 4000 The 20A DC STCS booster allows to perform resistance tests on a PT with a current up to 20 A DC. The option is used together with STS 5000 and STS 4000 and must be connected to STCS module.
MultiSafe DSP HS11 zweipoliger Hochspannungsprüfer zur Prüfung von Gleich- und Wechselspannung

MultiSafe DSP HS11 zweipoliger Hochspannungsprüfer zur Prüfung von Gleich- und Wechselspannung

Der MultiSafe DSP HS11 ist ein zweipoliger Hochspannungsprüfer zur Prüfung von Gleich- und Wechselspannung an Umrichtern und Einspeisungen von Verkehrsbahnanlagen. Der Hochspannungsprüfer ist Ideal für die Prüfung von Zwischenkreisen von Umrichtern, Kondensatorbatterien und Einspeisungen von Verkehrsbahnanlagen. Durch vollautomatische Messabläufe werden Bedienfehler ausgeschlossen. Drei Anzeigesysteme garantieren gute Wahrnehmung in allen Umgebungen. Der MultiSafe stellt sich automatisch auf die zu prüfende Spannung AC / DC ein. Pluspunkte • präzise Anzeige von Spannungen von 50 bis 11 000 V AC / 16 000 V DC • Eigentest (R-Test) zur Überprüfung der Schutzwiderstände und der Elektronik  • höchste Sicherheit durch vergossene Schutzwiderstände • Stoßspannungsfest über 300 kV • leichte Bedienung, eindeutige Signale, beleuchtetes Display • robustes Gehäuse wasser- und staubdicht – IP 65 Technische Daten Nennspannungsbereich:50-11.000 V AC / 16.000 V DC Frequenzbereich:0-500 Hz Stromversorgung:9V – 6LR61 / 6LF22 Frequenzanzeige:Ja Eigentest:Ja Schutzart:IP 65
M75 – Kompakter VDE 0100-Tester mit Multimeter & LAN-Test Funktionen

M75 – Kompakter VDE 0100-Tester mit Multimeter & LAN-Test Funktionen

Spannungsmessung AC/DC TRMS Widerstandsmessung Durchgangsprüfung Frequenzmessung Niederohmmessung mit 200mA (VDE 0413 Teil 4) Isolationsmessung 250V/500V DC (VDE 0413 Teil 2) Auslösezeit RCD (FI) (VDE 0413 Teil 6) Auslösestrom RCD (FI) (VDE 0413 Teil 6) Schleifenwiderstand (VDE 0413 Teil 3) Drehfeldrichtungsmessung (VDE 0413 Teil 7) LAN-Test VDE0100 Kombigerät mit allen Merkmalen eines Echt-Effektivwert-Multimeters (TRMS) zur Prüfung der elektrischen Installationen nach VDE0100 & VDE0105 Das Modell M75 ist ein innovatives Kombigerät mit allen Merkmalen eines Echt-Effektivwert-Multimeters (TRMS) für Prüfungen von elektrischen Installationen und Messungen an LAN-Netzkabeln. Als echtes Allroundgerät zeichnet es sich durch eine ergonomische, ästhetisch ansprechende Form, einen innovativen elektronischen Funktionswahlschalter sowie eine schnelle, einfache Bedienung und Ausführung der Tests aus. Alle Messungen gemaß VDE 0413 Teil 2, 3, 4, 6, 7. Gebrauch: Der Bereich MULTIMETER TRMS gestattet das Messen von V AC und DC sowie von Fehlerstrom mit externer Zange, Widerstand und Frequenz, der Bereich VDE 0100 die Ausführung von Tests gem. VDE 0100 (Durchgang mit 200 mA, Isolation mit 500 V, Schleifenwiderstand mit Kurzschlussstromermittlung, Auslösezeit und Auslösestrom vom RCD) mit innovativer AUTO-Funktion für die automatische Ausführung der Tests direkt an den Steckdosen der Anlagen durch Drücken einer einzigen Taste. Die Messung der Drehfeldrichtung der Phasen mit der patentierten Einpol-Methode komplettiert die Palette der Sicherheitsprüfungen. Der Bereich LAN-NETZWERKKONTROLLE ermöglicht schnelle Mappingkontrollen an allgemeinen LAN-Netzkabeln zur Aufdeckung der häufigsten Störsituationen.
PRÜFBALL ZAP350L / ZAP1050L – Robuster Spannungsprüfer mit Gummigehäuse und Zähleranlauftest

PRÜFBALL ZAP350L / ZAP1050L – Robuster Spannungsprüfer mit Gummigehäuse und Zähleranlauftest

Der Prüfball ZAP Digital ist ein sicheres Werkzeug zum schnellen Anlauftest bei der Inbetriebnahme von Stromzählern, kombiniert mit einem hochwertigen Spannungsprüfer. Sein ballartiges Gehäuse aus Gummi kapselt die Messelektronik ein und schützt optimal gegen harte Stöße, Wasser, Staub und elektrischen Schlag. Das macht den Prüfball unverwüstlich, sicher und langlebig. Spannungsprüfer: präzise Anzeige der Spannung 50 V bis 500 V AC / DC extrem Spannungsfest – CAT IV 500 V – VDE zertifiziert eindeutige LED-Anzeige für gefährliche Spannung 350 W / 1050 W Lastzuschaltung zum schnellen Zähleranlauftest und zur Erkennung von Störspannungen vollständige Spannungsanzeige ohne Batterie – wartungsfrei große LCD Anzeige mit Hintergrundbeleuchtung Durchgangsprüfer: schneller Durchgangstest Durchgangstest mit Anzeige bis 1000 kOhm Phasen- und Drehfeldrichtungsprüfer: Phasenprüfer mit Anzeige “POL” und roter LED Drehfeldprüfer mit LCD Anzeige rechts / linksController-überwachte Prüfung mit Fehlererkennung zur Vermeidung von Falschaussagen Phasen- und Drehfeldrichtungsprüfer können mit Handschuhen genutzt werden weitere Funktionen: Sicherheitsgehäuse aus Vollgummi extrem stoßfest Prüfelektroden mit Gewinde zum Aufschrauben von Zubehör leichte Bedienung Lastzuschaltung mit Thermo- und Überlastschutz extrem stabiles Gehäuse, auch bei Kälte IP 65 – wasserdicht
HT Instruments GSC53N Multifunktions VDE 0100-Tester mit 3-Phasen Netzanalyse

HT Instruments GSC53N Multifunktions VDE 0100-Tester mit 3-Phasen Netzanalyse

Messung + Kontrolle nach VDE0100, VDE0105, EN61557 + EN50160. Multifunktionsprüfgerät inkl. 3 Phasen Netz- + Leistungsanalysator,Oberwellenermittlung, Spannungsqualitätsanalyse nach EN50160 Messfunktionen und technische Merkmale: Große übersichtliche LCD Anzeige mit Hintergrundbeleuchtung Niederohmmessung mit > 200mA DC (VDE 0413 Teil 4, EN 61557-4) Isolationsprüfung mit 50,100,250,500 oder 1000V DC (VDE 0413 Teil 2, EN 61557-2) Komplette FI (RCD) Test und Analysefunktion (VDE 0413 Teil 6, EN 61557-6) Schleifen- und Netzimpedanzmessung (VDE 0413 Teil 3, EN 61557-3) Anzeige des Kurzschlußstromes Ik (VDE 0413 Teil 3, EN 61557-3) Schleifenwiderstandsmessung ohne Auslösung des FI Drehfeldrichtungsmessung (VDE 0413 Teil 7, EN 61557-7) Erdungsmessung und spez. Erdwiderstandsmessung (VDE 0413 Teil 5, EN 61557-5) Spannungsqualitätsüberwachung (EN50160) Netzanalyse & Leistungsmessung, Energieverbrauchsanzeige Oberwellenermittlung und Scope-Funktion Integrierte optische Schnittstelle auf USB Anschluss für 3 externe Stromzange 1mA bis 3000A Anschluss für externe Messsonden zur Feuchte-, Temperatur-, Licht und Schallpegelmessung Interner Meßwertspeicher für 800 Messwerte bzw. 2MB für Langzeitmessung Automatische Abschaltung Integriertes Gummi-Schutzholster Sicherheit nach IEC-1010-1, CAT III 415V Prüfung der Netzqualität nach EN50160 Das Modell GSC53N ermöglicht neben der VDE0100 Messung auch eine vollständige Überprüfung der Netzqualität an Ein- und Dreiphasensystemen, sowohl bei symmetrischer als auch unsymmetrischer Belastungen. Folgende Parameter können ermittelt werden: Spannungsschwankungen über die eingestellten Grenzwerte (Einbrüche und Spitzen) mit 10ms- Mindestauflösung Spannungsverlauf TRMS bis 600V Stromverlauf TRMS bis 3000A Oberwellen von Spannung und Strom bis zur 49. Ordnung Wirkleistung, Blindleistung, Scheinleistung Energieverbrauch Leistungsfaktor cos Bei einem Intervall von 15min und 63 ausgewählten Kanälen beträgt die Aufzeichnungskapazität mehr als 30 Tage.